• Z6·尊龙凯时「中国」官方网站

    Product catalog

    PN-2000FD Medical Respiratory Humidifier

    Contact Us
    Online Message
    Detail

    Medical respiratory humidifier PN-2000FD is a kind of heating and humidification equipment, specially designed for ventilators and other positive

    pressure ventilation systems. And a wet heating surface heated by gas, mechanical ventilation to reduce the irritation on the cardiopulmonary system. This can facilitate sputum suction and effectively prevent airway obstruction. We can not by adjusted to the same range of temperatures to achieve different and may independently monitor the temperature.

    Scope of application:

    matching with ventilator or positive pressure system, used for heating and humidifying breathing gas.

    Advantages:

    ● Using microcomputer processing, multi-point temperature setting, reliable and stable.

    ● Ergonomic design, compact and portable.

    ● Quick temperature adjustment, digital display, real-time monitoring, convenient and intuitive.

    ● Automatic temperature control, overheating (dry burning) protection, safe and effective.

    ● Accessories can be sterilized by routine or gas.

    Technical parameter

    Temperature ( outlet of humidification tank)

    Temperature control:                                    28℃~42℃

    Temperature control accuracy:                    ±2℃

    Humidity performance:                               at least 10mg/L

    Leakage:                                                      Leakage does not exceed 5mL/min

    Heating plate thermal cut:                          95±6℃

    Maximum water volume:                           230mL/240mL

    Working pressure:                                      ≤2kPa

    Flow:                                                          180L/min

    Pressure drop:                                          <300Pa


    Alarming

    Low humidity packet warning:                  

    -external temperature probe temperature <10 deg.] C      L audible alarm

    -Output gas temperature value <28℃,                               window flickering and audible alarm

    High humidity alarm:

    external temperature probe temperature> 45 deg.] C       H audible alarm

    Connection status alarm:

    heating plate temperature probe failure                            E6 audible alarm

    External temperature probe failure                                    E7 audible alarm                

    Mute:                                                                                   not less than 60s

    System noise:                                                                    ≤50dB (A)

    Power supply:                                                                     ac220V±22V, 50Hz±5Hz

    Power:                                                                                 85W

    Website links
    >1688 alibaba
    > alibaba.com

    > 3618med

    > merchants recruiting net

    >Made in China

    >MedicalExpo en
    >MedicalExpo cn
    友情链接: